Requirement of THERMOSTAT THERMOMETER
# |
Item |
Description |
Unit |
Quantity |
1 |
Thermostats
|
TEMP SW;THERMOSTAT THERMOMETER ,+30 TO 1
TYPE:TEMPERATURE SWITCH SENSING ELEMENT MATERIAL:THERMOSTAT
THERMOMETER BULB AND CAPILLARY MATERIAL:COPPER,TIN PLATED COPPER
MEASURING RANGE:+30 TO 110 °C CAPILLARY ARMOURING:YES CASE MATERIAL:
CAST ALUMINIUM OVER RANGE PROTECTION:120 °C SWITCH:SPDT
OUTPUT:240 V AC,3A CONTACT:1NO+1NC PROTECTION CLASS:IP 66
CONNECTION:1/2NPT(F) ACCESSORIES:NO ACCESSORIES POWER SUPPLY:10A 110-
250V AC/0.2A 110-250V SPECIAL FEATURES:NO SPECIAL FEATURES
Instruction to Vendor:
TEMPERATURE SWITCH SPECIFICATION:
Capillary Tube :2000 mm
Range :30-100 Deg C
Calibration Range :70 Deg C
Sensor Size (Ø x L) :9mm X 80 mm
Sensor Type :Remote Bulb
Adjustable diff. range setting :0-20 Deg C
Enclosure :IP66
Reset Function :Auto
Electrical Contact :1NO + 1NC
Electrical connection :1/2 NPT F
Process connection Accessories :Supply with 1/2 NPT F capillary tube gland with required accessories. |
Nos
|
View
|